Cement Meets Polyurethane: How Hybrid Injections Are Changing Tunnelling

A cement-polyurethane injection combines a cement suspension and a reactive polyurethane resin in a single injection process. The cement provides volume stability and cost-efficiency, while the polyurethane governs reactivity and resistance to washing-out. This was made possible by the bypass mixing system developed by RASCOR in 2018. In q/p tests based on the Lombardi method, the hybrid product RASCOhybrid HMS317 shows up to 90 per cent less washing-out than a pure cement suspension, and it is used in projects such as the Semmering and Brenner base tunnels.

Water-bearing zones in rock mass are among the most demanding challenges in tunnelling. High pressure, uncontrollable inflows, unstable rock, and always the pressure of the schedule. For a long time civil engineers faced one fundamental question: cement or polyurethane? The next-generation answer is both together.

Two Materials, Two Strengths and One Weakness 

Conventional injection methods work either with a cement suspension or with reactive resins. Cement is inexpensive and readily available, but under the action of water it can be washed out before it sets. Polyurethane is reactive and resistant to washing-out, but considerably more expensive. Earlier attempts to combine the two failed because of insufficient homogenisation: two hoses running in parallel did not mix the components evenly.

How the Bypass Mixing System Delivered the Breakthrough

The decisive step came in 2018, when RASCOR developed its own bypass mixing system. For the first time this allowed a reproducible, inline homogenisation of PU and cement. The PU can be metered in steplessly during the injection process, so that reaction time, viscosity and penetration behaviour are adjusted in real time. Two separate methods became one single, homogeneous system: RASCOhybrid HMS317.

Hybrid Injection Compared with the Individual Methods Too

Criterion

Pure cement suspension

Pure polyurethane

Cement-PU hybrid

Material costs

Low

High

Medium

Resistance to washing-out

Low

High

High (up to 90% less washing-out)

Volume stability

High

Lower

High

On-site adaptability

Low

Medium

High, steplessly adjustable

Suitability at high water pressure

Limited

Good

Very good

 

Three Benefits That Count in Practice

Greater stability and watertightness. In q/p tests based on the Lombardi method, PU-cement mixtures showed up to 90 per cent less washing-out than pure cement suspensions. Where pure cement would be washed away, the hybrid system holds.

Flexibility and adaptability. The mixing ratios can be matched to the ground conditions live. In zones with moderate water flow more cement can be used, which saves costs. In heavily loaded zones a higher PU content increases safety.

Cost and environmental benefits. Despite the higher material price of PU, the total costs often fall significantly: fewer injection passes, less material loss, fewer construction delays. Fully reacted mixtures such as RASCOhybrid HMS317 are considered inert and can usually be landfilled as a non-hazardous mineral building material.

From Practice: Where the Hybrid System Proves Itself

Pilot applications from 2019, routine use since 2020. Today RASCOhybrid HMS317 is used in the Semmering Base Tunnel, at the Helgoland harbour mole, in the Brenner Base Tunnel and in other demanding projects. In reference projects watertightness was achieved even under high rock-water pressures and in saline water, where conventional injection methods reach their limits.
Frequently Asked Questions about Cement-PU Hybrid Injection
What is a cement-polyurethane injection?

An injection method that combines a cement suspension and a reactive polyurethane resin in a single operation. The cement provides volume stability and cost-efficiency, the polyurethane provides reactivity and resistance to washing-out.

Because of their differing physical and chemical properties, the materials do not mix homogeneously without suitable technology. Only the bypass mixing system developed in 2018 made a reproducible inline homogenisation possible.

In q/p tests based on the Lombardi method, PU-cement mixtures showed up to 90 per cent less washing-out than pure cement suspensions. This is particularly decisive in strongly water-bearing zones.

Fully reacted mixtures are considered inert. Eluate tests according to DIN 19631 show no relevant release of pollutants. Disposal is usually possible as a non-hazardous mineral building material.

Demanding conditions in tunnel, shaft and hydraulic construction, especially high inflow rates, pressurised water or saline water. It is used in the Semmering and Brenner base tunnels, among others.

Conclusion

The combined cement-polyurethane injection is more than a technical trick. It represents a new generation of injection technology: more precise, more resource-efficient and more robust in practice than ever before.

Are you planning a project with demanding water flow? The RASCOR specialists will assess whether a hybrid system is the right fit. Contact: +41 44 857 11 11 or sales@rascor.com.